Scroll Top
Elite City Building, Opposite JM Mall, Samora Avenue, Dar es Salaam, Tanzania
+255 22 2126966

A Scan

Appascan Max (A Scan)

Technical Specifications

A-scan Probe
Probe frequency10 MHZ
FixationInternal LED
Measurement range
Axial Length14.0 mm to 40.0mm
ACD2.0 mm to 6.0 mm
Lens Thickness2.0 mm to 7.5mm
Measurement Accuracy± 0.1mm
Measurement Techniques
MethodImmersion / Contact
ModeAuto / Manual
Lens TypeAphakic, Normal, Cataract, Dense Cataract, Pseudophakic (Silicone, PMMA,Others), Silicone Oil
IOL Calculation
FormulaeSRK-T, SRK II, Holladay, Binkhorst, Hoffer-Q, Haigis, AME*, and Post Refractive Formulas
DisplayHigh resolution 8 inch colour display With Touch screen
Control
Storage100 patient records, 10 Preset User, 25 IOL configurations
Camp ModeFast Measurement with IOL calculation in single screen
PrinterFast Thermal printer with Auto cutter
Power
Electrical Requirements230V AC / 50HZ

Other Features

  •  Auto / Manual Gain
  •  Automatic calculation of standard deviation and average axial length (series of 10 measurements)
  •  Simultaneous display of 3 different IOL calculations
  •  RTC shows the Date and Time throughout the life of the instrument.
  •  Various user Programmable printouts Format
  •  Measurement possible for Various Velocity of each segment .
  •  *AME Formula – The new generation programmed software takes care of any Axial Length.

Accessories

  •  Soundless Motorized Stand

Appascan Max with Pachymeter

Technical Specifications

ASCAN PROBE
Probe Frequency10MHZ
FixationInternal LED
Measurement range
Axial Length14.0 mm to 40.0mm
ACD2.0 mm to 6.0 mm
Lens Thickness2.0 mm to 7.5mm
Measurement Accuracy+ 0.1 mm
Measurement Techniques
MethodImmersion / Contact
ModeAuto / Manual
Lens TypeAphakic, Normal, Cataract, Dense Cataract, Pseudophakic, ( Silicone, PMMA, Others ) Silicone Oil
IOL Calculation
FormulaeSRK – T, SRK – II, Holladay, Binkhorst, Hoffer-Q, Haigis, AME* and Post Refraction Formulae
Display ControlHigh resolution 8 inch colour display With Touch screen
Storage100 Patient records, 10 preset users 25 IOL Configuration
Camp ModeFast measurement with IOL calculation In single screen Printer
printerFast Thermal printer with Auto Cutter
Power
Electrical Requirements230V AC / 50Hz
PACHYMETER Specifications 🙁 General )
Measurement Range200- 1000 microns
Accuracy+ or – 5 microns
Frequency20MHz
CommunicationRS232 for PC connection

IOP Adjust Software

  •  Easily Adjust IOP based on measured CCT.
  •  CCT measurements
  •  Guaranteed fast and easy Measurements

Scan Modes

  •  Continuous/Mapping
  •  User programmable Mapping (up to 10 maps)

Measurements

  •  Adjustable Corneal Velocity
  •  Automatic Sensing Algorithm
  •  Measurement Review
  •  100 Scan Average with Standard Deviation

Probe

  •  20 MHz Angled or Straight

Other Features

  •  Auto / Manual Gain
  •  Automatic calculation of stamdard deviation and average axial length ( serial of 10 measurement )
  •  Simultaneous display of 3 different IOL calculation
  •  RTC shown the Date Time throughout the life of the instrument.
  •  Various user Programmable printouts format
  •  Measurement possible for various velocity of each segment.
  •  *AME Formula – The new generation programmed software takes care of any Axial Length.